CMS8000 VET Veterinary ICU Vital Signs Patient Monitor
Description
Introduction
The CMS8000VET Veterinary Monitor has abundant monitoring functions and can be used for monitoring of cat, dog and other animals. User may select different parameter configurations according to different requirements. It adopts 100-240V

,50/60Hz for power supply, 12.1'' TFT color LCD for displaying real-time data and waveform, and up to 8-channel waveform and all monitoring parameters can be displayed simultaneously. In addition, it can be connected to the central monitoring system via wired/wireless network so as to form a network monitoring system.
This device can monitor such parameters as ECG, RESP, NIBP, SpO2 and dual- channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. At the same time, its built-in replaceable battery provides convenience for moving.
Functions
Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
1)ECG   Heart rate (HR)
ECG waveform
Arrhythmia and ST-segment analysis
2)RESP   Respiration rate(RR)
Respiration waveform
3)SpO2   Oxygen saturation(SpO2)
Plethysmogram(PLETH) waveform
Pulse rate(PR)
Bar graph
4)NIBP   Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
5)TEMP   T1, T2, TD
It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc
Features
1)12.1'' TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakhstan, Polish, Czech).
2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
3)With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe.
4)Operation mode: keys and buttons.
5)Display up to 8-channel waveform on one screen.
6)Display 7-lead ECG waveform on one screen, and with ECG step function.
7)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
8)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
9)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
10)Drug concentration calculation and titration table functions.
11)Print trend table data with one-key.
12)Connect to Central Monitoring System by 3G, WiFi or wired mode.
13)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
14)Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).
Performance
▲ECG
Lead mode:       3-lead or 5-lead
Lead selection:      I, II, III, aVR, aVL, aVF, V
Waveform:       5-lead, 2-channel
3-lead, 1-channel
Gain:        2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
Scan speed:       12.5mm/s, 25 mm/s, 50 mm/s
HR:
Measurement and alarm range:  15~350bpm
Accuracy:     ±1% or ±1bpm, whichever is greater
Alarm accuracy:     ± 2 bpm
Resolution:      1 bpm
ST-segment monitoring:
Measurement and alarm range:  -2.0mV~+2.0mV
Accuracy:     -0.8mv~+0.8mv  ±0.04mv or ±10%, whichever is greater
Other range: unspecified
Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,
PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Pacemaker:       yes
▲RESPIRATION
Method:       R-F(RA-LL) Impedance
Respiration rate:
Measurement and alarm range: 0~150rpm
Resolution:     1 rpm
Measurement accuracy:   ±2 rpm
Alarm accuracy:    ±3 rpm
Apnea alarm:     10~40s
Scan speed:     6.25 mm/s, 12.5 mm/s, 25 mm/s
▲NIBP
Method:       Oscillometry
Mode:       Manual/AUTO/STAT
Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes
Measurement period in STAT mode: 5 minutes
Measurement and alarm range:  10 ~ 270 mmHg
Resolution:      1 mmHg
Cuff pressure accuracy:    ±3 mmHg
Measurement accuracy:
Maximal mean error:   ±5 mmHg
Maximal standard deviation:  8mmHg
Over-pressure protection:
Other mode:     297±3 mmHg
Dog mode:     240±3 mmHg
Cat mode:     147±3 mmHg
▲SpO2
Measurement and alarm range:  0 ~ 100%
Resolution:      1%
Measurement accuracy:    70%~100%: ±2%;
0%~69%: unspecified
▲PR
Measurement and alarm range:  30 ~ 250 bpm
Measurement accuracy:    ±2 bpm or ±2%, whichever is greater
▲TEMP
Channel:       dual-channel
Measurement and alarm range:  0 ~ 50℃
Resolution:      0.1 ℃
Accuracy:      ±0.1 ℃
▲Power supply:    100-240V

,50/60Hz
▲Safety classification:   Class I, type CF defibrillation-proof applied part
Accessories
1)Digital BD7 veterinary tongue-clip SpO2 sensor (1M)
2)General digital SpO2 sensor extension cable (2M)
3)Neonatal capsule single tube repeatable cuff (6-11cm)
4)NIBP extension tube
5)5-lead ECG lead cable (American-Standard)
6)ECG veterinary clip (*5)
7)Transvaginal TEMP probe
8)Power cord
9)User Manual
Shipping
1. We will ship the item within 2 days after receiving your payment.
2. All items will be shipped to buy's ebay address. Please check your ebay address  is right.
3.The item will be declared as lower value for shipping only.We'd like to cooperate with you and declare the value of  it as you want us to,so that it is easier for you to clear the custom.
International Buyers - Please Note:
* Import duties, taxes and charges are not included in the item price or shipping charges. These charges
are buyers' responsibility.
* Please check with your country customs office to determine what additional costs will be prior to bidding OR buying.
Terms of Sale
Returns:
We offer 60 days return policy. 100% satisfaction is our goal!
1.All items are brand new ,with 1 year warranty.
2.If you have a defective item, you want to return or discount. Please contact us within 2 days from you receive the shipment.
3.We will refund the money to you when we get the return items or replace item for you.
4. All return items must be returned with it's original packaging and accessories. Customer is responsible for shipping charges on returned items.
Feedback
please leave me a positive feedback if you are satisfied with our products, thanks!
I will appreciate your positive feedback so much,and in any case or some problem with the products, please contact us before leaving Neutral OR Negative Feedback. I am sure I will give you a satisfied answer, thank you.
Buy safe products
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.
The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The  Fingertip Pulse Oximeter that is FDA 510K Approved
About Us
CONTEC Medical System----Focusing on research, manufacture and distribution of medical equipment,
CONTEC Medical System was founded in 1992 as a professional medical equipment producer.
At present,there are more than 1200 employees in our company .Our product lines cover a wide range of 13 categories,and have been distributed over 30 countries.
We are the manufacture of medical equipment for more than 20 years, main products include ECG machine,
Patient monitor,EEG machine,pulse oximeter,Fetal doppler,Blood pressure monitor and so on.
Contact Us
We are Professional Manufacturer--CONTEC MEDICAL SYSTEMS CO.,LTD
Looking forward to establishing a successful business relationship with you.
Contact Person:Vivian Zhang
Address(US): 1440 Chase Avenue,Elk Grove Village,Illinois 60007 United States
Only English User manual,Please contact us if you need other language version.