We aremanufacturer: Contec Medical Systems
Patient Monitor 6 Parameter,ECG,NIBP,PR,Spo2,Temp,Resp,CE,FDA
CONTEC NEW 15" Color ICU/CCU Patient Monitor
Model:CMS9200
ETCO2+IBP+Printer is option
Introduction
This equipment can monitor such parameters as ECG, RESP, NIBP, SpO
2
, PR, Dual- channel TEMP, dual-channel IBP and EtCO2. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. At the same time, its built-in replaceable battery provides convenience for patient moving. This equipment adopts full-isolation(floating), ECG defibrillation-proof protection, ECG anti-high frequency interference and NIBP dual-protection for over-pressure, to ensure monitoring quality and reduce operation risk, which is applicable for monitoring adult, pediatric and neonate.
Features
Elegant appearance, clear marks, standard interface, oxygen graph, trend graph, big characters, other BED observation, which are convenient for users.
Standard parameters: ECG, RESP, NIBP, SpO
2
and dual-channel TEMP. IBP, CO2 and built-in printer are optional.
Fifteen languages are optional, and all operations can be finished by keys and buttons.
15'' color LCD displays patient parameter and waveform collected, and alarm, bed NO., clock, equipment state and other information provided by the monitor synchronously.
Monitoring parameters, scan speed, volume and output contents can be set optionally.
Storage of 480-hour trend data, and review of 34-second holographic waveform.
Adopt digital SpO
2
technology, strong in anti-interference and anti-weak filling capability.
Calculation of drug concentration.
Built-in rechargeable battery for uninterrupted monitoring.
Print ECG, SpO
2
, RESP, BP and TEMP data with one-key.
Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads).
Optional functions: Moving bracket, hanging bracket, VGA output and and 12-lead.
Specification
Safety classification:
Type of protection against electroshock: Class I
Degree of protection against electroshock: type CF defibrillation-proof applied part
Degree of protection against ingress of water: IPX0
Environment requirement:
Temperature:
Working: 5~40(℃)
Transport and storage: -40~+55(℃)
Humidity
Working: 30%~75%
Transport and storage: ≤95%(no coagulation)
Power supply
Power supply: AC100~240V, 50/60 (Hz)
Maximal input power: 150VA
Battery
Working time: 90 minutes
Display
Waveform: display 8-channel waveform in a screen
Color: waveform and parameter color can be set
Waveform and parameter selection: parameter and waveform need to be displayed can be selected, and waveform position also can be adjusted.
Alarm
Alarm items: technical alarm, 71 physiological alarms and 60 arrhythmia alarms.
Prompt mode: visible, audible and character alarm (3 alarm levels)
Trend review
Time: trend review for 480-hour, review for 2400 groups of BP data
Review mode: trend graph and trend table
SD card review: trend review and review for 72-hour ECG waveform
Network
Network mode: wired, WIFI, 3G
Connection contents: connect to central monitor system by LAN or WAN; View bed
Updating mode
Software updating: network updating and U disk updating
ECG
Lead mode: 3-lead or 5-lead
Lead selection: I, II, III, aVR, aVF, aVL, V
Gain: ×0.25, ×0.5, ×1, ×2
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
HR:
Measurement and alarm range
Adult: 15~300bpm
Pediatric and neonatal: 15~350bpm
Accuracy: ±1% or ±1bpm, whichever is greater
ST segment monitoring:
Measurement and alarm range: -2.0mV~+2.0mV
Accuracy: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is greater
Other range: unspecified
Arrhythmia analysis: 13-arrhythmia
Volume: 0~7
Pacemaker: yes
RESPIRATION
Method: R-F(RA-LL) Impedance
Check range for respiration impedance: 0.3~5Ω
Measurement and alarm range for RESP rate: 0~120rpm
Accuracy: ±2 rpm
Apnea alarm: 10~40s
Scan speed: 6.25mm/s, 12.5mm/s, 25 mm/s
NIBP
Method: Oscillometry
Measurement and alarm range:
Adult
Systolic: 40~270mmHg
Diastolic: 10~215 mmHg
Mean: 20~235 mmHg
Pediatric
Systolic: 40~200mmHg
Diastolic: 10~150 mmHg
Mean: 20~165 mmHg
Neonate
Systolic: 40~135 mmHg
Diastolic: 10~100 mmHg
Mean: 20~110 mmHg
Inflation time: <30s(10~270 mmHg, standard adult cuff)
Measurement time: <40s
Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90 minutes
Accuracy for BP measurement: ±5mmHg, maximal standard deviation: 8mmHg
Over-pressure Protection:
Adult Mode: 297±3 mmHg
Pediatric Mode: 240±3 mmHg
Neonatal Mode: 147±3 mmHg
TEMP
Channel: dual-channel
Measurement Range: 0 ~ 50℃
Accuracy: 0.1℃
Display resolution: 0.1℃
Updating time: about 1s
SpO
2
Measurement Range: 0 ~ 100 %
Measurement accuracy :70%~100%: ±2%;
0%~69%: unspecified
Display resolution: 1%
Upper and lower limit for alarm: 0~100%
Measurement and alarm range for PR: 0~250bpm
Measurement accuracy for PR: ±2bpm or ±2%, whichever is greater.
Pulse modulation volume: yes
Printer (optional)
Waveform: 2-channel
Print width: 48mm
Paper speed: 25mm/s, 50mm/s
EtCO2(optional)
Method: Sidestream or Mainstream
Measurement Range for CO2: 0~150mmHg
Resolution for CO2:
0.1 mm Hg: 0 to 69 mm Hg
0.25 mm Hg: 70 to 150 mm Hg
Accuracy for CO2:
0 – 40 mm Hg: ±2 mm Hg
41 – 70 mm Hg :±5%
71 – 100 mm Hg :±8%
101 – 150 mm Hg :±10%
Respiration Rate>80BPM: ±12%
AwRR Range: 0~150 rpm
Apnea Alarm: yes
IBP(optional)
Channel: dual-channel
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measurement and Alarm Range: -10~300 mm Hg
Resolution: 1 mm Hg
Accuracy: ±2% or 1mm Hg, whichever is greater
Physical characteristic
Dimension: 363 x 168 x 339 (mm)(L×W×H)
Weight: 4.9kg
Accessories
User Manual
Adult fingertip SpO
2
probe (5-pin)
NIBP extension tube
NIBP metal plugs
Adult NIBP cuff
ECG lead wire(American standard)
ECG electrode
Temperature probe
Power cord
ECG Cable
Disposable Sticky Electrodes
NIBP Connector
Adult BP Cuff
Temperature Sensor
SPO2 Sensor
Terms of Sale
Returns:
We offer 60 days return policy. 100% satisfaction is our goal!
1.All items are brand new ,with 1 year warranty.
2.If you have a defective item, you want to return or discount. Please contact us within 2 days from you receive the shipment.
3.We will refund the money to you when we get the return items or replace item for you.
4. All return items must be returned with it's original packaging and accessories. Customer is responsible for shipping charges on returned items.
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.
The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The Fingertip Pulse Oximeter that is FDA 510K Approved
International Buyer--Please note:
Import duties,Taxes are not included in the item price.These charges are buyers' responsibility
We are the manufacturer of medical equipment for 17 years, the following are our main products:
ECG / ECG holter EEG / EEG Holter B-ultrasound
Patient Monitor Fetal doppler Fetal Monitor
Spo2 Monitor Stethoscope Medical Image....
Agent in the world!
We are look for partners in the world now!
Do you want to become our agent in you conutry?
Join US!
Mary
Sky--pe:xuebox3
contec.med.mary # hotmail dot com
Only English User Manual,Please contact us if you need other language version.thank you