-40%
Portable Vital Signs Patient Monitor 6-Parameters Hospital ICU CCU Monitor
$ 221.23
- Description
- Size Guide
Description
12.1-inch display 6-parameter Patient Monitor----ECG, NIBP, SPO2, TEMP, RESP, PR
Model: RPM-9000A
Features:
Ergonomic design, portable, convenient for use
12" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
Unique digital SPO2 technology can work accurate during motion and low perfusion
Anti AC & high-frequency electrosurgical & defibrillator’s interference
Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
Audible & visual alarm available, adjustable
Patient information management function
Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
Optional software upgrading based on USB
Wired/wireless networking with central monitoring system, up to 64 beds in one group
Built-in 3 trace thermal recorder for printing real-time and historical data
Multi-language i.e. English, Spanish, Turkish.
Super long life rechargeable Lithium battery upto 4 hours of working time
Suitable for adult, pediatrics and neonate patients
Standard configuration:
ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery
Optional:
Dual TEMP
Dual IBP
ETCO2 (side stream)
Thermal recorder
Wall mount
Trolley
Specification:
ECG
Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate:
Scope: 15 times/minute to 300 times/minutes
Accuracy: ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
Accuracy: Error rate < 20%
Undetected rate < 20%
ST section
Scope: ±0.8mV
Precision : < ±0.05mV
SpO2
Detection scope: 0%-100%
Accuracy ±1% 90%-100%
±2% 70%-89%
NIBP
Theory Electric oscillator
Cuff gassing time less than 15 seconds
First-time gassing : dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min(90 min -240min)
Detection scope:
Systolic blood presure: 4kPa -34kPa(30mmHg -255mmHg)
Diastolic presure 2kPa -29.3kPa(15mmHg -220mmHg)
Mean presure 2.7kPa~31.3kPa (20mmHg~235mmHg)
Detection accuracy
Static presure: ±3mmHg
Pulse rate: ±2%
Resp
Chest impedance method or concentration of carbon dioxide at end of respiration
Scope of chest impedance method 0 time/minute – 100 minutes/minute
Precision of chest impedance method time/minute
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
Detection precision of respiration rate: ±1 time/minute
Temp
Single/double path
Type: Vascular/surface temperature
Scope: 20℃~50℃
Accuracy: ±0.2℃
Payment
We accept PayPal only. We will ship out the item after receiving cleared payment.
Shipping
A complete and correct shipping address is essential.
Customers with shipping addresses outside of the U.S. are responsible for all duties and import taxes. Please contact your customs for information
Return Policy
All items are in brand new condition unless specified.
FDA declaration:
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item. (Seller Name: Christine Geng;Country: China;City: Beijing;TEL.:86-15210656055).
This item has been cleaned and treated according to the manufacturer's instructions.
The Powered Surgical Instrument / Speed 808 System is certified with the US FDA 510(k) Number:K132989
The Powered Surgical Instrument / Hair Remove Device
is certified with the US FDA 510(k) Number:K180353
The Powered Surgical Instrument / Hair Remove System