-40%

USA 12" ICU CCU 6-parameter Patient Monitor ECG NIBP SPO2 TEMP RESP, PR +Printer

$ 361.67

Availability: 100 in stock
  • Country/Region of Manufacture: China
  • Return shipping will be paid by: Seller
  • Refund will be given as: Money Back
  • Standard configuration: ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery
  • All returns accepted: Returns Accepted
  • Warranty: 2 year
  • Brand: Unbranded
  • UPC: Does not apply
  • Item must be returned within: 30 Days
  • MPN: Does Not Apply
  • Support: support use in NICU, ICU, OR, CCU or normal patient room
  • Multi-language: English, Spanish, Turkish
  • Bundle Listing: Yes
  • Restocking Fee: No
  • EAN: Does not apply
  • Condition: New
  • Model: RPM-9000A
  • Display: 12" TFT display
  • Alarm Type: Audible & visual alarm
  • Herstellernummer: nicht zutreffend

    Description

    Product Overview
    USA 12" ICU CCU 6-parameter Patient Monitor ECG NIBP SPO2 TEMP RESP, PR +Printer
    Detail
    Description:
    Model: RPM-9000A    SKU:800060
    12-inch ICU CCU 6-parameter Patient Monitor
    Features for Patient Monitor:
    Ergonomic design, portable, convenient for use
    12" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
    Unique digital SPO2 technology can work accurate during motion and low perfusion
    Anti AC & high-frequency electrosurgical & defibrillator’s interference
    Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
    Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
    ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
    Audible & visual alarm available, adjustable
    Patient information management function
    Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
    Optional software upgrading based on USB
    Wired/wireless networking with central monitoring system, up to 64 beds in one group
    Built-in 3 trace thermal recorder for printing real-time and historical data
    Multi-language i.e. English, Spanish, Turkish.
    Super long life rechargeable Lithium battery upto 4 hours of working time
    Suitable for adult, pediatrics and neonate patients
    Standard configuration:
    ECG, NIBP, SPO2, TEMP, RESP, PR, Printer, Rechargeable Lithium battery
    Optional:
    Dual TEMP
    Dual IBP
    ETCO2 (side stream)
    Wall mount
    Trolley
    Specification for Patient Monitor
    :
    ECG
    Full lead: I, II, III, AVL, AVR, AVF and V
    Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
    Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
    Band width: 0.05Hz-100Hz(3dB)
    Heart rate:
    Scope: 15 times/minute to 300 times/minutes
    Accuracy:  ±1 time/minute
    Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
    Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
    Accuracy: Error rate < 20%
    Undetected rate < 20%
    ST section
    Scope:     ±0.8mV
    Precision :  < ±0.05mV
    SpO2
    Detection scope:   0%-100%
    Accuracy         ±1%     90%-100%
    ±2%      70%-89%
    NIBP
    Theory Electric oscillator
    Cuff gassing time   less than 15 seconds
    First-time gassing pressure: dynamic state 24kPa(180 mmHg)
    Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
    18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
    Automatic detection period: 1 minute to 240 minutes
    Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
    in -90min) and 30min(90 min -240min)
    Detection scope:
    Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg)
    Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg)
    Mean pressure               2.7kPa~31.3kPa       (20mmHg~235mmHg)
    Detection accuracy
    Static pressure: ±3mmHg
    Pulse rate:  ±2%
    Resp
    Chest impedance method or concentration of carbon dioxide at end of respiration
    Scope of chest impedance method     0 time/minute – 100 minutes/minute
    Precision of chest impedance method  time/minute
    Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
    Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
    Detection precision of respiration rate: ±1 time/minute
    Temp
    Single/double path
    Type:    Vascular/surface temperature
    Scope:    20℃~50℃
    Accuracy:  ±0.2℃
    Invasive blood pressure (optional)
    Single/double path
    Type: direct and continuous detection
    Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
    Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)  13.33k
    Pa(100mmHg) above ±2%
    Frequency response:DC-12Hz
    Input resistance: not less than 500kΩ
    Sensitivity of sensor: 5μV/V/mmHg
    Motivation voltage:5V (DC)
    Accuracy of sensor: ±2%Isolation voltage: 4 kV
    Shipping Policy
    Payment Mathord
    Returns Policy
    About Feedback
    Contact US
    Shipping Policy
    1. We accept PAYPAL payment only and ship to your eBay address.
    2. Item will be shipped within 1 business days after received a verified payment.
    3. Shipped by air mail which normally takes 7-14 business days to USA, 12-25 business days to other countries.
    4. Delivery Time upon purchase Locations
    >>>Australia, South East Asia and Asia
    15-18 working days
    >>>United Kingdom, United States and Canada
    8-21 working days
    >>>Europe, South America, Middle-East Asia
    16-28 wrokging days
    >>>Italy and Brazil (because of strict custom inspection)
    28-56 working days
    Payment Mathord
    1. PayPal payment accepted only.
    2. Items will be shipped to your eBay address. Please make sure it is correct.
    3. Payment must be received 4 days after auction ended.
    Returns Policy
    1. Customer satisfaction is our top goal. We believe our items are so outstanding. All products are quality checked. They are new and in good condition when shipped to our customers. We are convinced you will be happy with your Purchase.
    2. If product is defective or damage upon arrival, or wrong product shipped, please contact us immediately. Returns accepted within 14 days of delivery date and item must be in original new condition, not worn or altered in any way with attached tags & wrap. Otherwise deal is final. Return shipping must be paid by buyer.
    3. Please contact us first if you have any problems/questions/concerns. We will be happy to resolve any issues you may have in a cordial and friendly manner.
    4. We appreciate your Postive Feedback, and will do the same in return. DO NOT leave negative feedback without first communication with us. Please allow max 2 business days for us to response.
    About Feedback
    When you satisfied with our product and services please leave us positive feedback.
    If a problem occurs, contact us immediately with any email request. We promise we will give you the satisfied solution. :)
    Contact US
    The seller’s name: Alice
    City:Beijing
    State: Beijing
    Country: China
    Telephone number: 86-18305265146
    FDA Disclaimer:
    Statement: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
    The Fingertip Pulse-Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 136606, and certified by FDA of United States (Premarket Submission Number (510K): K073454 Listing Number: D045684, K082641 Listing Number: D064765, K090671 Listing Number: D078664); and CE Approved, TUV of Europe (Cert.No. : G1 10 02 50972 013). You can consult with the FDA's Center for Devices and Radiological Health