USA Medical Vital Sign Patient Monitor ECG NIBP RESP TEMP SPO2 PR Cuff +Cable CE
$ 189.55
- Description
- Size Guide
Description
Product OverviewUSA Medical Vital Sign Patient Monitor ECG NIBP RESP TEMP SPO2 PR Cuff +Cable CE
Detail
Description:
Portable Patient Monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP. It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. Large high-resolution display provides clear view of 5 waveforms and full monitoring parameters.
Features:
8 inch TFT color screen
Exquisite design suitable to moving operation
Various interfaces: standard screen, trend screen, oxyCRG screen, NIBP list screen, big front screen.
Real-time S-T segment analysis, pace-maker detection.
Built-in rechargeable lithium battery, convenient for patient moving.
Suitable for adult, pediatric and neonatal patient
Standard Configuration:
SpO2, PR, NIBP, ECG, RESP, TEMP
Technical Parameters:
ECG:
Lead Mode:5 Leads (
R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection:I, II, III, avR, avL, avF, V,
Waveform:2 ch
Gain:2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
Heart Rate:15-300BPM(Adult) 15-350BPM(Neonatal)
Accuracy:± 1% or ± 1bpm,which great
Resolution:1 bpm
ST measurement Range:-2.0-+2.0mV
Sweep Speed:12.5 mm/s,25mm/s,50mm/s
Alarm:Available
Review:Available
RESP:
Method Impedance between R-F(RA-LL)
Measuring Range:Adult
0 ~ 120 rpm,Neo/Ped 0 ~ 150 rpm
Resolution:1 rpm
Accuracy:
±
2 rpm
NIBP:
Method:Oscillometric
Mode:Manual, Auto, STAT
Measuring and alarm range
Adult Mode
SYS:40 ~ 270 mmHg
DIA:10 ~ 215 mmHg
MEAN:20 ~ 235 mmHg
Pediatric Mode
SYS:40 ~ 200 mmHg
DIA:10 ~ 150 mmHg
MEAN:20 ~ 165 mmHg
Neonatal Mode
SYS:40 ~ 135 mmHg
DIA:10 ~ 100 mmHg
MEAN:20 ~ 110 mmHg
Resolution:1mmHg
Accuracy:+-5mmHg
SpO2:
Measuring Range:0 ~ 100 %
Alarm Range:0 ~ 100 %
Resolution:1 %
Accuracy:70% ~ 100%
±
2 %
Actualization interval:about 1 Sec.
Alarm Delay:10 Sec.
Pulse Rate :0~254bpm
Resolution:1bpm
Accuracy:
±
2bpm
Temperature:
Measuring and Alarm Range:0 ~ 50 C
Resolution:0.1C
Accuracy:0.1C
Actualization interval:about 1 Sec.
Average Time Constant:< 10 Sec.
Package List:
Patient monitor
Temperature probe
ECG lead cable
ECG electrode
Adult NIBP cuff
NIBP extension tube
Adult fingertip SpO2 probe
Power cord
User Manual
Shipping Policy
Payment Mathord
Returns Policy
About Feedback
Contact US
Shipping Policy
1. We accept PAYPAL payment only and ship to your eBay address.
2. Item will be shipped within 1 business days after received a verified payment.
3. Shipped by air mail which normally takes 7-14 business days to USA, 12-25 business days to other countries.
4. Delivery Time upon purchase Locations
>>>Australia, South East Asia and Asia
15-18 working days
>>>United Kingdom, United States and Canada
8-21 working days
>>>Europe, South America, Middle-East Asia
16-28 wrokging days
>>>Italy and Brazil (because of strict custom inspection)
28-56 working days
Payment Mathord
1. PayPal payment accepted only.
2. Items will be shipped to your eBay address. Please make sure it is correct.
3. Payment must be received 4 days after auction ended.
Returns Policy
1. Customer satisfaction is our top goal. We believe our items are so outstanding. All products are quality checked. They are new and in good condition when shipped to our customers. We are convinced you will be happy with your Purchase.
2. If product is defective or damage upon arrival, or wrong product shipped, please contact us immediately. Returns accepted within 14 days of delivery date and item must be in original new condition, not worn or altered in any way with attached tags & wrap. Otherwise deal is final. Return shipping must be paid by buyer.
3. Please contact us first if you have any problems/questions/concerns. We will be happy to resolve any issues you may have in a cordial and friendly manner.
4. We appreciate your Postive Feedback, and will do the same in return. DO NOT leave negative feedback without first communication with us. Please allow max 2 business days for us to response.
About Feedback
When you satisfied with our product and services please leave us positive feedback.
If a problem occurs, contact us immediately with any email request. We promise we will give you the satisfied solution. :)
Contact US
The seller’s name: Alice
City:Beijing
State: Beijing
Country: China
Telephone number: 86-18305265146
FDA Disclaimer:
Statement: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
The Fingertip Pulse-Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 136606, and certified by FDA of United States (Premarket Submission Number (510K): K073454 Listing Number: D045684, K082641 Listing Number: D064765, K090671 Listing Number: D078664); and CE Approved, TUV of Europe (Cert.No. : G1 10 02 50972 013). You can consult with the FDA's Center for Devices and Radiological Health